DDG-208 Industrial Conductivity Meter
DDG-208
Industrial Conductivity Meter
the Industrial Conductivity Meter is With strong environmental adaptability, clear display, easy
operation and excellent measuring performance, the DDG-208 Intelligent On-line
Conductivity Meter has very high performance-price ratio. It can be widely used
for continuous monitoring of the conductivity values of the solutions used in
the following industries: thermal power plants, chemical industry, chemical
fertilizer, metallurgy, environmental protection, pharmacy manufacturing,
biochemistry, foodstuff and running water.
Features of Industrial Conductivity Meter
Fully intelligent: Industrial Conductivity Meter adopts
high-precision AD conversion and single chip microcomputer processing
technologies
|
and can be used for
conductivity and temperature measurement, automatic temperature compensation,
automatic
|
range switching,
self-checking, etc.
|
Multi-parameter display: The
conductivity and temperature values can be displayed on the same screen at
the
|
same time. It adopts LED
display module with high brightness. the displayed values can be seen from
|
along distance away.
|
Strong
interference immunity: Its current output adopts optoelectronic isolating
technology. This meter has
|
stronginterference
immunity and the capacity of long-distance transmissionas well as excellent
electromagnetic
|
compatibility.
|
25℃ Conversion: The conductivity value measured at the current
temperature is converted to that at 25℃;
|
thus, this
conductivity meter always displays the conductivity value at 25℃. Therefore, this meter is especially
|
suitable for testing
the various water solutions in power plants.
|
Technical Indexes of Industrial Conductivity Meter
1. Standard:
JB/T6855-93 《Industrial Conductivity Meter》
|
2. Conductivity
measuring range: 0.01~20µS/cm(Electrode: K=0.01)
|
0.1~200µS/ cm
(Electrode: K=0.1)
|
1.0~2000µS/ cm
(Electrode: K=1.0)
|
10~20000µS/ cm
(Electrode: K=10.0)
|
3. Accuracy:
conductivity: ±1.0%FS; temperature: ±0.5℃
|
4. Intrinsic error
of electronic units: conductivity: ±0.5%F.S, temperature: ±0 3℃(0~60℃)
|
5. Range for
automatic temperature compensation: 0~80℃, with 25℃ as the reference temperature
|
6. Water sample tested:
0~80℃, 0.6Mpa
|
7. Intrinsic error
of the instrument: conductivity: ±1.0%F.S, temperature: ±0.5℃(0~60℃)
|
8. Automatic temperature compensation error of the electronic unit: ±0.5%FS |
9. Repeatability
error of the electronic units: ±0.2%FS±1 unit
|
10. Stability of the
electronic unit: ±0.2%±l unit FS/24H
|
11. Alarm error of
the electronic unit: ≤±3.0%FS
|
12. Error of
electronic unit caused by ambient temperature: ≤±0.5%FS
|
13. Error of the
electronic unit caused by the supply voltage: ≤±0.3%FS
|
14. Isolated current
output: 4~20mA (load<750kΩ)
|
15. Output current
error of the electronic units: ≤±l.0%FS
|
16. Alarm relay:
AC220V, 3A
|
17. Communication
interface: RS485(optional)
|
18. Power supply: AC
220V±22V, 50Hz±1Hz, DC24V(optional)
|
19. Protection grade:
IP65
|
20. Overall
dimension: 146 (length) x 146 (width) x 108 (depth) mm; dimension of the
hole: 138 x 138mm
|
21. Weight: 0.6kg
|
22. Working
conditions: ambient temperature: 0~60℃; relative humidity <85%
|
23. The connection
tubes for inlet and outlet water: Hard pipe or soft pipe.
|