DOG-2082D Dual Channel Industrial Dissolved Oxygen Meter
DOG-2082D Dual
Channel Industrial Dissolved Oxygen Meter
DOG-2082D Industrial Dissolved
Oxygen Meter is a kind of high-intelligence on-line meter that is developed by
our company and used for continuous on-line monitoring. It can be equipped with
DOG-208F Polarographic Electrode and can automatically switch from ppb level to
ppm level of wide-range measurement. This instrument is designed for monitoring
the oxygen content in the boiler feed water, condensate water and sewage. Dual
channel dissolved oxygen meter, one instrument can connect 2 wastewater
dissolved oxygen electrode at the same time.
Features of Dual Channel Industrial Dissolved Oxygen Meter
|
Complete English display, English menu operation: Liquid crystal
display module with high resolution is
|
|
adopted. All the data, status and operation prompts are
displayed in English.
|
|
Multi-parameter
display: The oxygen concentration value, input current (or output
current), temperature time
|
|
and status can be
displayed on the screen at the same time. The main display can show the
oxygen concentration
|
|
value, hilite, far visual
range. Sub-displays can display such information as the input or output
current
|
|
temperature, status,
week, year, month, day, hour, minute and second etc, so as to adapt to
different users’ habits
|
|
and provide reference
times of instrument.
|
Technical Indexes of Dual Channel Industrial Dissolved Oxygen Meter
|
1. Measuring range:
0~100.0ug/L; 0~20.00 mg/L
(automatic switching); 0~60℃, 0~150℃(optional)
|
|
Resolution: 0.1ug/L;
0.01 mg/L; 0.1℃
|
|
2. Intrinsic error
of the whole instrument: ug/L: ±l.0%FS; mg/L: ±0.5%FS, temperature: ±0.5℃
|
|
3. Repeatability of the indication of the whole instrument: ±0.5%FS
|
|
4. Stability of the
indication of the whole instrument: ±1.0%FS
|
|
5. Automatic temperature compensation range: 0~60℃, with 25℃ as the
reference temperature.
|
|
6. Response time:
<60s (98% and 25℃ of the final value) 37℃: 98% of the final value < 20
s
|
|
7. Clock accuracy: ±1 minute/month
|
|
8. Output current
error: ≤±l.0%FS
|
|
9. Isolated output: 0-10mA (load resistance <1.5KΩ);
|
|
4-20mA (load resistance
<750Ω)
|
|
10. Communication interface: RS485 (optional)
|
|
11. Saving time of
data under a continuous power-failure condition: 10 years
|
|
12. Power supply: AC220V±10%, 50±1HZ, DC24V(optional)
|
|
13. Overall
dimension: 146 (length) x 146 (width) x 108 (depth) mm;
|
|
Dimension of the hole: 138 x 138mm
|
|
14.Weight:0.8kg
|
|
15. Working
conditions: ambient temperature: 0-60℃; relative humidity <85%
|
|
16. The connection
tubes for inlet and outlet water: Pipes and hoses
|

评论