CLG-2086 Industrial Water Chloride ION Concentration Meter

CLG-2086 Industrial Chloride Concentration Meter
CLG-2086 chloride concentration is a high intelligent online continuous monitoring instrument, including the sensor and the secondary meter of two parts. It can be widely monitoring lakes water, surface water, water plant, sewage treatment plant, enterprises discharge waste water in water continuous monitoring. Random offers a variety of commonly used ion mode such as: H+, Ag+, Na+, K+, NH4+, cl-, F-, NO3-, BF4-, CN-, Cu2+, Pb2+, and support for user-defined ion mode, measurement of other ions.

Features
Computer-based: Multi-parameter measurement, temperature compensation and automatic range conversion
are achieved thanks to the high-performance CPU chip, high-precision AD conversion technology and SMT
pasting technology, resulting in high precision and repeatability.
High reliability: Single-board structure, touch keys, no switch knob or potentiometer. Rapid response,
accurate;
Water proof and dust-proof design: Its protection grade is IP54. It is applicable for outdoor use.
Electromagnetic compatibility (EMC/RFI) design: according to European standard EN50081 /50082
fabrication.
Alarm: Isolated alarm signal output, discretionary setting of upper and lower thresholds for alarming, and
lagged cancellation of alarming.
History curve: It can continuously record data for a month, with a point for each five minutes.
Notepad function: Recording 200 messages.
Instrument not crash: Watchdog procedures to ensure that the instrument will not working continuously crash
Offline measurement: Instead of laboratory sodium meter, performance can mark fluid examination  
instrument. The use of low cost, small amount of maintenance.

Technical Indexes
1. Measuring range:  chlorine concentration value: 0 ~ 5000 mg/L,     division value: 0.01mg/L;                                                     
                               temperature: 0~99.9℃;         division value: 0.01
                             potential value: - 1999 ~ +1999mV,  division value: 0.1mV;
2. Resolution: chlorine concentration value:±2.5% , temperature:± 0.5
3. Automatic temperature compensation range:: 099.9℃,with 25 as the reference temperature

4. Accuracy:±2.5%,±0.3
5. Water sample tested:: 099.9, 0.6MPa
6.Automatic temperature compensation error of the electronic unit: ±1.5%
7.Repeatability error of the electronic unit: ±0.02pH
8. Stability:±1.5%/24h
9. Clock accuracy: ±1 minute/month
10. Isolated current output: 4-20mA (load resistance <750Ω)
11. Output current error: ≤±l%FS
12. Data storage capacity: l month (1 point/5 minutes)
13. High and low alarm relay: AC220V, 7A

14. Communication interface: RS485(optional)
15.Power supply: AC220V±22V, 50Hz±1Hz,24VDC(optional)
16. Protection grade: lP65
17. Overall dimension: 146 (length) x 146 (width) x 108 (depth) mm;
dimension of the hole: 138 x 138mm
18. Weight: 1.0 kg
19. Working conditions: ambient temperature: 0-60℃; relative humidity: <85